HEAT EXCHANGER, Noninsulated

REKA heat exchanger including built-in storing tank with domed end plated made of 4 mm tank plate. The heat exchanger is normally applied if it is not possible - due to large difference in heights - to connect the existing boiler and the solid fuel boiler and this ensure that the expansion tank is placed as high up as necessary.

1.             2" Flow / Solid Fuel Boiler and Expansion Tank

2.             2" Return / Solid Fuel Boiler

3.             1 ½" Flow / Oil Burner

4.             1 ½" Return / Oil Burner


 

Litre

S in mm

H in mm

Weight

Empty

1500

1000

2000

435

2000

1500

2500

560

2500

2000

3000

680

3000

2000

3500

740

Example of a Solid Fuel Boiler with Thermo-Syphon
Action, Storing Tank, and Oil Burner.

     1.             Oil Burner

     2.             Solid Fuel Boiler

     3.             Heat Exchanger and Storing Tank

     4.             Open Expansion Tank ( 4½ %)

     5.             Air Escape

     6.             Possible Automatic Ventilation

     7.             Drain Valve

     8.             Closing Valves

     9.             Expansion Tank, open - or Pressure Tank

 10.             Existiong Circulation Pump

 11.             Hot-Water Tank