The REKA automatic stoker can be installed on any boiler
with a large firebox, an open bottom and a fireproof base.
In reality stoker combustion means fedding from the bottom
and effect from the top, or in other words the fuel is supplied from the bottom
and burns from the top. This principle of combustion produces particulary
favourable efficency (80-90%) as the fuel is heated and gasified at the bottom,
and the gas is pressed through the layer of glows i.e. high temperatures. The
ash will always be fully burnt out and will be pushed along the sides of the
boiler (i.e. disposal af ash at long interwals)
|
|
|
|
|
The REKA stoker consists of:
Silo base with feeder, engine and gear, reservoir with
level control,
dosimeter with a continuously variable geared engine, airtight lock,
stoker pipe and endless screw engine and gear,
airboz with retort (cooling trought), cast grid blocks,
combustion blower with engine and damper, electricity panal etc.
|
|
|
A.
Boiler
B.
Base for automatic stoker
C.
BS-60 wall
D.
Silocontainer
E.
Chimney
F.
Automatic stokerconstruction for straw, chips, sawdust, flakes etc.
|
|
|
|

A. Chimney
B.
Boiler
C.
Airbox with retort
D.
Call sluice
E.
Non return valve
F.
Dressure storage tank (water)
G.
Trap strainer
H.
Double thermic valve (sprinkler)
I.
180 deg. nozzle (sprinkler)
K.
Pressure control (sprinkler)
L.
Combustion blower
M.
Geared engine
N.
Dosing worm (screw)
O.
Continuausly variabel geared engine
P.
Reservoir with level control
Q.
Automatic stokerconstruction
R.
Silo base with feeder
S.
Silo/contatiner
T.
Cyklone
U.
Feeding worm (screw)
|
|